ABB MS132-32 Manual Motor Starter Product ID:1SAM350000R1015

This item is available ex-stock, subject to prior sale.  Item condition: brand-new, unused, undamaged.
Please email sales@sanhat.com.pk or call 0333 454 1983 for further assistance, thank you.

Manual Motor Starter
ABB MS132-32 Manual Motor Starter
Product ID:1SAM350000R1015
15.5kW; 208÷690VAC;
DIN; Short circ.release:480A
Make: ABB, Origin: Germany



General Information
Extended Product Type:MS132-32
Product ID:1SAM350000R1015
EAN:4013614400155
Catalog Description:MS132-32 Manual Motor Starter
Long Description:The MS132-32 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 32.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC and trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
Dimensions
Product Net Width:45 mm
Product Net Height:97.8 mm
Product Net Depth / Length:86.55 mm
Product Net Weight:0.31 kg
Technical
Rated Service Short-Circuit Breaking Capacity (Ics):(230 V AC) 25 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 25 kA
(440 V AC) 20 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 20 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):480 A
Setting Range:25 ... 32 A
Rated Operational Power AC-3 (Pe):(400 V) Three Phase 11 kW
Rated Operational Voltage:Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie):32 A
Rated Operational Current AC-3 (Ie):32 A
Rated Operational Current DC-5 (Ie):32 A
Rated Frequency (f):Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):Main Circuit 6 kV
Rated Insulation Voltage (Ui):690 V
Power Loss:at Rated Operating Conditions per Pole 1.9 ... 3.1 W
Number of Poles:3
Conventional Free-air Thermal Current (Ith):Main Circuit 32 A
Degree of Protection:Housing IP20
Main Circuit Terminals IP10
Pollution Degree:3
Electrical Durability:50000 cycle
Mechanical Durability:100000 cycle
Terminal Type:Screw Terminals
Connecting Capacity Main Circuit:Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Tightening Torque:Main Circuit 2 N·m
Wire Stripping Length:Main Circuit 10 mm
Recommended Screw Driver:Pozidriv 2
Mounting Position:Position 1 to 6
Mounting on DIN Rail:TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:Rotary Handle
Contact Position Indication:ON / OFF / TRIP
Standards:IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
Remarks:UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Technical UL/CSA
Short-Circuit Current Rating (SCCR):Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600 V AC) 18 kA
Maximum Operating Voltage UL/CSA:Main Circuit 600 V AC
Ampere Rating UL/CSA:32 A
Horsepower Rating UL/CSA:(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
Full Load Amps Motor Use:(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 27 A
Locked Rotor Amps:(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 146 A
General Use Rating UL/CSA:(600 V AC) 32 A
Connecting Capacity Main Circuit UL/CSA:Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Tightening Torque UL/CSA:Main Circuit 18 in·lb
Environmental
Ambient Air Temperature:Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:Yes
Maximum Operating Altitude Permissible:2000 m
Resistance to Shock acc. to IEC 60068-2-27:11 ms Pulse 25g
Resistance to Vibrations acc. to IEC 60068-2-6:5g / 3 ... 150 Hz
RoHS Status:Following EU Directive 2011/65/EU
Certificates and Declarations (Document Number)
ABS Certificate:1SAA963001-0101
ATEX Certificate:1SAA963000-3902
BV Certificate:1SAA963001-0202
CB Certificate:1SAA963002-2001
CCC Certificate:1SAA963001-3805
cUL Certificate:cUL_E137861
cUL_E345003
cULus Certificate:cUL_E137861
Declaration of Conformity - CE:1SAD938511-0125
DNV GL Certificate:1SAA963001-0304
EAC Certificate:1SAA963000-2701
GOST Certificate:1SAA963001-2702
Instructions and Manuals:2CDC131022M6802
LR Certificate:1SAA963001-0502
RINA Certificate:1SAA963000-0802
RMRS Certificate:1SAA918000-0704
RoHS Information:1SAD938511-0125
Time-Current Characteristic Curve:1SAM300505F0015
UL Certificate:UL_E137861
UL_E345003
Container Information
Package Level 1 Units:1 piece
Package Level 1 Width:92 mm
Package Level 1 Depth / Length:102 mm
Package Level 1 Height:50 mm
Package Level 1 Gross Weight:0.325 kg
Package Level 1 EAN:4013614400155
Package Level 2 Units:40 piece
Package Level 2 Width:280 mm
Package Level 2 Depth / Length:395 mm
Package Level 2 Height:210 mm
Package Level 2 Gross Weight:13.386 kg
Package Level 2 EAN:4013614409059
Classifications
Object Classification Code:F
ETIM 4:EC000074 - Motor protective circuit-breaker
ETIM 5:EC000074 - Motor protective circuit-breaker
ETIM 6:EC000074 - Motor protection circuit-breaker
ETIM 7:EC000074 - Motor protection circuit-breaker
eClass:7.0 27370401
UNSPSC:39121521

Stock Clearance Sale Items
© 2013-2021, Sanhat Private Limited.
SANHAT Private Limited (Established 2013)
A-4/18, H-Commercial, Valencia, Lahore-54600, Pakistan
Landline: +92 (042) 3522 5805-07, Ext: 803 and 820
Email: sales@sanhat.com.pk
Registered in
Back to content